Avoid corrosion caused by chimney deposits
The fall out from boilers and heaters using wood, oil and other fuels can be unsightly and if neglected, damage the surface under which it falls
While it is not always possible to prevent this happening it can be reduced by locating the flue or exhaust in a position where prevailing winds would blow the fallout clear of the roof.
It is most important to ensure that the height of the flue is sufficient to create a good draft which will also result in reducing the concentration of the fallout.
The design of the flue must meet the appropriate Australian Standard AS 2918 - 1990 and meet appropriate Local Government building ordinances.
Corrosion has been found to be related to elevated concentrations of sulphurous products, wood acids and resinous combustion products which have condensed directly from the exiting flue gas. This is associated with the fuel type, and/or inappropriate flue design.
Burning of green hardwood, resinous soft woods, low grade coal or oils with a high sulphur content can all result in greater quantities of fallout which contain corrosive substances.
Where the skin temperature of the flue is low due to poor design or the use of single tube flue systems, cooling of the flue gas will occur.
This results in precipitation of the flue gas components and deposition of the heavier particles on the roof surface adjacent to the flue.
For more information, download "Corrosion Technical Bulletin 14 - Exhaust from Wood and Oil Fire Burners".